P-Series Specification |
||
Standard |
Option |
|
| Type | Cage Induction | Slip Ring |
| Frame Sizes | 450 to 1400 | |
| Output | Up to 20000kW @ 4-pole speed | |
| Voltage | 3150 to 13800V | Others |
| Mounting | Horizontal or Vertical | |
| Frequency | 50Hz or 60Hz | Variable Frequency Supply |
| Poles | 2 to 16 | Others, Multiple-pole |
| Cooling | CacA (TEAac) CacW (TEWac) | Open Ventilated NEMA I or II |
| Ingress Protection | IP55 | IP22 to IP 56 |
| Mounting (EN 60034-7) | IM1001, IM7011 & IM7211, IM3011 | Others |
| Temperature Rise | Class B | Class F |
| Duty | S1 | Others |
| Insulation | Class F, VPI | Class H, VPI |
| Bearings | Grease Lubricated, Rolling Element Bearings | Oil - Lubricated Sleeve Bearings (Standard on some sizes) |
| Main Terminal Box | Air Insulated for fused supplies Or Elastomeric termination | Phase Insulated, Phase Segregated, BEAMA/CEGB, Others |
| Ambient Temperature | -20OC to +40OC | -50OC to +60OC |
| Starting | Design N | Design D, Low Starting Current, High Starting Torque |
| Starting Method | DOL | Others |
| Noise Level, Mean Sound Pressure Level, @ 1m, No Load | 81 dB(A) | Refer to manufacturer for lower noise level. |
| Vibrations | Grade R to EN60034.14 | API 541 Ed 3 |
| Standards | EN60034-1, IEC 72: Pt 2 | NEMA MG1, Customer Specific |
| Area Classification | Safe Area | EEx n to EN50014/21, EEx e to EN50014/19, EEx p to En50014/16 |
Site Map | Contact Us | ©2007-2010 ATB Laurence Scott Ltd