| Standard | Option | |
| Type | Cage Induction | - |
| Frame Sizes | 355 to 500 | - |
| Output | 125 - 1500kW @ 4-pole speed | |
| Voltage | 3300, 4160, 6600 | Other voltages to 13.8kV |
| Mounting | Horizontal or Vertical | - |
| Frequency | 50Hz or 60Hz | Variable Frequency Supply |
| Poles | 2 to 8 | Others, Multiple-pole |
| Cooling | Air Cooled, TEFC, IC4A1A1 | - |
| Ingress Protection | IP56 | - |
| Mounting (EN 60034-7) | IM2001 - Horizontal Foot, IM3011 - Vertical Flange | IM2001 - Horz. Foot and Flange, IM3811 - Vertical Skirt |
| Temperature Rise | Class B | Class F |
| Duty | S1 | Others |
| Insulation | Class F, VPI | Class H, VPI |
| Bearings | Grease Lubricated, Rolling Element Bearings | Oil - Lubricated Sleeve Bearings (std on 500 2-pole) |
| Main Terminal Box | Air Insulated for fused supplies | Phase Insulated, Phase Segregated, BEAMA/CEGB, Elastomeric termination |
| Ambient Temperature | -20OC to +40OC | -50OC to +60OC |
| Starting | Design N | Design D, Low Starting Current, High Starting Torque |
| Starting Method | DOL | Others |
| Noise Level, Mean Sound Pressure Level, @ 1m, No Load | 2-pole: 81 dB(A) , 4-pole and up: 80 dB(A), (60Hz +3dB) | Refer to manufacturer for lower noise level. |
| Vibrations | Grade R to EN60034.14 | API 541 Ed 3 |
| Standards | EN60034-1, IEC 72: Pt 2 | NEMA MG1, Customer Specific |
| Area Classification | Safe Area | EEx n to EN50014/21, EEx e to EN50014/19, EEx p to En50014/16 |